Allen Bradley PanelView Plus 700, PanelView Plus 1000 and PanelView PluS 1250.
Touchscreen compatibility after upgrading to our LED kit varies depending on the Allen-Bradley PanelView mainboard model. If your touchscreen does not function properly after installation, please follow the instruction below:
Open back cover, Remove front panel assembly and Remove LCD screen
Identify the mainboard part number and compare with the below table
Identify UIJ Chip and remove pin 2 from circuit board on the mainboard as shown photo
That is it! Now it should solve the touch problem. If the problem still exists, Please email your request to techsupport@lcdparts.net along with a few images of your mainboard.
This modification procedure can apply to the following brand and models:
Manufacturer CAT Mainboard
PanelView Plus 700 2711P-RDB7C SER C 77158-729-51
PanleView Plus 700 2711P-RDB7C SER D 77158-729-51
PanelView Plus 700 2711P-RDT7C SER C 77158-729-51
PanelView Plus 1000 2711P-RDB10C SER B PN-27832
PanelView Plus 1000 2711P-RDT10C SER B PN-27832
PanelView Plus 1250 2711P-RDB12C SER C REV C A77158-787-51
PanelView Plus 1250 2711P-RDB12C SER C A77158-787-51
PanelView Plus 1250 2711P-RDT12C SER C A77158-787-51
Youtube Instruction